Radiography (X-ray and gamma)
In one sentence: radiography passes X-rays or gamma rays through a part onto a film or a digital detector; denser or thicker material absorbs more, so voids, cracks and hidden objects show up as differences in the image.
How it works
A source (an X-ray tube or a gamma isotope such as iridium-192 or cobalt-60) is placed on one side, a film or digital detector on the other. The image is a shadow of everything along the path. A void, porosity or slag in a weld absorbs less and shows darker on film; a dense inclusion shows lighter. Image quality indicators placed on the part show that the image is sharp enough.
Uses
- Welds: porosity, slag, lack of fusion, cracks oriented along the beam, in pipes, plates and structural welds. Codes like AWS D1.1 and ASME give acceptance criteria. ASTM E94 is a general guide.
- Concrete: locating bars, tendons and ducts and checking grout in post-tensioning ducts, in members thin enough to penetrate.
- Castings and components.
Digital radiography
Computed radiography (imaging plates) and direct digital detectors replace film in much field work: faster results, image enhancement and electronic storage.
Radiation safety
Radiography is the NDT method with the most serious safety requirements:
- Only licensed operators and radiation safety officers, under a state radioactive material or X-ray license.
- A controlled exclusion zone with barriers, signs and survey meters, often at night or when the area can be cleared.
- Personal dosimeters for every radiographer.
- Secure storage and transport of gamma sources.
Limits
- Cracks show only when they line up with the beam.
- Access to both sides is needed.
- Site disruption from the exclusion zone; often UT is chosen instead for welds.
Common mistakes
- Scheduling radiography during working hours on a busy site.
- Concluding "no cracks" from radiographs when cracks may run across the beam.
- Missing image quality indicators on the images.